Parallel Outputs
Two status outputs are provided. They are dry contact closures
rated at 24 VDC and 1 amp max. Their function is described
below.
Function Pin No’s. Description
Playing Universe 1 1,20 Closed when the unit is playing DMX data
from a Cue Name on this Universe.
Playing Universe 2 2,21 "
Playing Universe 3 3,22 "
Playing Universe 4 4,23 "
Fault Universe 1 5,24 Closed when the unit detects an invalid file
for playback or other error on that Universe.
Fault Universe 1 6,25 "
Fault Universe 1 7,26 "
Fault Universe 1 8,27 "